Cross-discipline design-contradiction checker for construction drawing sets. Standalone tool broken out from Iron_Bid; a pipeline stage may later fold back into Iron_Bid. Pipeline: PDF->images -> per-sheet assertion extraction -> deterministic clustering by location -> per-cluster reasoning -> report. Includes CLI (cli/run_check.py) and web UI (backend/main.py). Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
1 line
4.2 KiB
JSON
1 line
4.2 KiB
JSON
{"sheet_number": "G31.06", "discipline": "General", "sheet_title": "UL RATINGS - DESIGN #U419", "level": null, "scale": null, "assertions": [{"assertion_id": "G31.06-001", "subject": "Fire Resistance Assembly", "category": "wall_partition", "attribute": "wall_rating", "value": "1, 2, 3, or 4 Hour", "unit": "Hr", "location_key": {"sheet_number": "G31.06", "grid": null, "room": null, "room_name": null, "level": null, "tag": "U419", "detail_reference": "DESIGN No. U419", "plan_zone": null}, "source_text": "Nonbearing Wall Ratings -- 1, 2, 3 or 4 Hr (See Items 4 & 5 through 5J)", "coordination_targets": ["architectural", "life_safety", "code", "structural"], "conflict_potential": "high", "code_review_relevance": "high", "confidence": "high"}, {"assertion_id": "G31.06-002", "subject": "Fire Resistance Assembly", "category": "note", "attribute": "UL Certification", "value": "BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States", "unit": null, "location_key": {"sheet_number": "G31.06", "grid": null, "room": null, "room_name": null, "level": null, "tag": "U419", "detail_reference": "DESIGN No. U419", "plan_zone": null}, "source_text": "BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States", "coordination_targets": ["architectural", "life_safety", "code"], "conflict_potential": "low", "code_review_relevance": "high", "confidence": "high"}, {"assertion_id": "G31.06-003", "subject": "Fire Resistance Assembly", "category": "note", "attribute": "UL Certification", "value": "BXUV7 - Fire Resistance Ratings - CAN/ULC S101 Certified for Canada", "unit": null, "location_key": {"sheet_number": "G31.06", "grid": null, "room": null, "room_name": null, "level": null, "tag": "U419", "detail_reference": "DESIGN No. U419", "plan_zone": null}, "source_text": "BXUV7 - Fire Resistance Ratings - CAN/ULC S101 Certified for Canada", "coordination_targets": ["architectural", "life_safety", "code"], "conflict_potential": "low", "code_review_relevance": "high", "confidence": "high"}, {"assertion_id": "G31.06-004", "subject": "1-Hour Rated Wall Assembly U419", "category": "wall_partition", "attribute": "wall_rating_assembly", "value": "Min 1-5/8\" stud depth with 1 layer of 5/8\" thick gypsum board on each side.", "unit": null, "location_key": {"sheet_number": "G31.06", "grid": null, "room": null, "room_name": null, "level": null, "tag": "U419", "detail_reference": "Gypsum Board Protection on each side of Wall Table", "plan_zone": null}, "source_text": "Rating, Hr: 1, Min Depth, In. (Item 2): 1-5/8, No. of Layers & Thickness of Panel: 1 layer, 5/8 in. thick", "coordination_targets": ["architectural", "structural", "code", "life_safety"], "conflict_potential": "high", "code_review_relevance": "high", "confidence": "high"}, {"assertion_id": "G31.06-005", "subject": "2-Hour Rated Wall Assembly U419", "category": "wall_partition", "attribute": "wall_rating_assembly", "value": "Min 2-1/2\" stud depth with 1 layer of 1/2\" thick gypsum board on each side.", "unit": null, "location_key": {"sheet_number": "G31.06", "grid": null, "room": null, "room_name": null, "level": null, "tag": "U419", "detail_reference": "Gypsum Board Protection on each side of Wall Table", "plan_zone": null}, "source_text": "Rating, Hr: 2, Min Depth, In. (Item 2): 2-1/2, No. of Layers & Thickness of Panel: 1 layer, 1/2 in. thick", "coordination_targets": ["architectural", "structural", "code", "life_safety"], "conflict_potential": "high", "code_review_relevance": "high", "confidence": "high"}, {"assertion_id": "G31.06-006", "subject": "2-Hour Rated Wall Assembly U419", "category": "wall_partition", "attribute": "wall_rating_assembly", "value": "Min 1-5/8\" stud depth with 2 layers of 1/2\" thick gypsum board on each side.", "unit": null, "location_key": {"sheet_number": "G31.06", "grid": null, "room": null, "room_name": null, "level": null, "tag": "U419", "detail_reference": "Gypsum Board Protection on each side of Wall Table", "plan_zone": null}, "source_text": "Rating, Hr: 2, Min Depth, In. (Item 2): 1-5/8, No. of Layers & Thickness of Panel: 2 layers, 1/2 in. thick", "coordination_targets": ["architectural", "structural", "code", "life_safety"], "conflict_potential": "high", "code_review_relevance": "high"}]} |