Files
Conflict_Checker/backend/.llm_cache/59e2537a261853b30c5d3008889b9b5f8eefae97441653ed9ef7448b67aaa80e.json
T
woogiandClaude Opus 4.8 1d248a8808 Initial commit: Conflict Checker
Cross-discipline design-contradiction checker for construction drawing
sets. Standalone tool broken out from Iron_Bid; a pipeline stage may
later fold back into Iron_Bid.

Pipeline: PDF->images -> per-sheet assertion extraction -> deterministic
clustering by location -> per-cluster reasoning -> report.
Includes CLI (cli/run_check.py) and web UI (backend/main.py).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 00:22:02 +00:00

1 line
1.9 KiB
JSON

{"sheet_number": "G11.02", "discipline": "General", "sheet_title": "SYMBOLS & TYPICAL HEIGHTS", "level": null, "scale": null, "assertions": [{"assertion_id": "G11.02-ACC-001", "subject": "Door Threshold", "category": "accessibility", "attribute": "max_level_change", "value": "1/4", "unit": "in", "location_key": {"sheet_number": "G11.02", "grid": null, "room": null, "room_name": null, "level": null, "tag": null, "detail_reference": "STANDARD TAS DOOR THRESHOLD HEIGHT", "plan_zone": null}, "source_text": "1/4\" MAX", "coordination_targets": ["architectural", "code", "ada"], "conflict_potential": "medium", "code_review_relevance": "high", "confidence": "high"}, {"assertion_id": "G11.02-ACC-002", "subject": "Door Threshold", "category": "accessibility", "attribute": "max_bevel_slope", "value": "1:2", "unit": null, "location_key": {"sheet_number": "G11.02", "grid": null, "room": null, "room_name": null, "level": null, "tag": null, "detail_reference": "STANDARD TAS DOOR THRESHOLD HEIGHT", "plan_zone": null}, "source_text": "1/2\" MAX", "coordination_targets": ["architectural", "code", "ada"], "conflict_potential": "medium", "code_review_relevance": "high", "confidence": "high"}, {"assertion_id": "G11.02-ACC-003", "subject": "Accessible Counter", "category": "accessibility", "attribute": "min_knee_clearance_width", "value": "36", "unit": "in", "location_key": {"sheet_number": "G11.02", "grid": null, "room": null, "room_name": null, "level": null, "tag": null, "detail_reference": "STANDARD TAS COUNTER HEIGHTS & CLEARENCES", "plan_zone": null}, "source_text": "36\" MIN", "coordination_targets": ["architectural", "code", "ada"], "conflict_potential": "medium", "code_review_relevance": "high", "confidence": "high"}, {"assertion_id": "G11.02-ACC-004", "subject": "Accessible Counter", "category": "accessibility", "attribute": "max_height", "value": "34", "unit": "in", "location_key": {"sheet_number": "G11.02"}}]}