Files
Conflict_Checker/backend/.llm_cache/733ba8263f08d2d9523e74558798e6ff595e89c907ea1e82f4535f8ee5e2e52e.json
T
woogiandClaude Opus 4.8 1d248a8808 Initial commit: Conflict Checker
Cross-discipline design-contradiction checker for construction drawing
sets. Standalone tool broken out from Iron_Bid; a pipeline stage may
later fold back into Iron_Bid.

Pipeline: PDF->images -> per-sheet assertion extraction -> deterministic
clustering by location -> per-cluster reasoning -> report.
Includes CLI (cli/run_check.py) and web UI (backend/main.py).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 00:22:02 +00:00

1 line
8.5 KiB
JSON

{"issues": [{"issue_id": "VZN_CYP_001", "source_stage": "code", "category": "ada_review", "severity": "high", "confidence": "high", "location": "Men's Restroom (103) and Women's Restroom (102)", "disciplines": ["Architectural"], "sheets": ["A51.01"], "description": "The doors to the single-user restrooms swing into the clear floor space required for the lavatory (L-1). This is not permitted unless specific conditions are met.", "evidence": [{"discipline": "Architectural", "sheet": "A51.01", "source_text": "WOMEN'S / RESTROOM, PLAN 1/2\" = 1'-0\"", "asserted_value": "Door swings into lavatory clear floor space"}, {"discipline": "Architectural", "sheet": "A51.01", "source_text": "MEN'S RESTROOM, PLAN 1/2\" = 1'-0\"", "asserted_value": "Door swings into lavatory clear floor space"}], "recommended_resolution": "Verify that a clear floor space of at least 30 inches by 48 inches is provided within the restroom, beyond the arc of the door swing, to meet Exception 2 of ADA 603.2.3. If this space is not available, the door swing must be reversed or the layout reconfigured so the door does not swing into any fixture's required clear floor space.", "code_reference": "ADA 603.2.3"}, {"issue_id": "VZN_CYP_002", "source_stage": "code", "category": "ada_review", "severity": "medium", "confidence": "high", "location": "Lounge", "disciplines": ["Architectural"], "sheets": ["A51.01"], "description": "The employee lounge sink is shown with a standard cabinet underneath, which likely does not provide the required knee and toe clearance for a forward approach.", "evidence": [{"discipline": "Architectural", "sheet": "A51.01", "source_text": "3'-0\"", "asserted_value": "36"}], "recommended_resolution": "Confirm the approach type for the lounge sink. If a forward approach is required, revise the cabinetry detail to provide knee and toe clearance compliant with ADA 306. Alternatively, confirm if a parallel approach is acceptable per ADA 606.2 Exception 1 (e.g., if it's considered a wet bar) and ensure clear floor space for a parallel approach is provided.", "code_reference": "ADA 606.2"}, {"issue_id": "VZN_CYP_003", "source_stage": "code", "category": "ada_review", "severity": "medium", "confidence": "high", "location": "Inventory Room", "disciplines": ["Architectural", "Electrical"], "sheets": ["A24.01"], "description": "Electrical outlets in the Inventory room are specified to be mounted at 60 inches above the finished floor, which exceeds the 48-inch maximum high reach range for accessible operable parts.", "evidence": [{"discipline": "Architectural", "sheet": "A24.01", "source_text": "(2) 20A, OUTLETS AT 60\" A.F.F.", "asserted_value": "60"}], "recommended_resolution": "Relocate the outlets to a height within the accessible reach range (typically 15\" min to 48\" max AFF). If the outlets serve a dedicated use and are not for general use, add a note to clarify this and confirm the exception in ADA 205.1 applies.", "code_reference": "ADA 205.1"}, {"issue_id": "VZN_CYP_004", "source_stage": "code", "category": "tas_tdlr", "severity": "medium", "confidence": "medium", "location": "Sales Area", "disciplines": ["Architectural", "Interiors"], "sheets": ["A22.01"], "description": "Pendant lights (L-6) in the Sales Area are noted to be mounted at 5'-5\" (65 inches) AFF. If these fixtures are located above a circulation path, they would be a head-height obstruction, violating the 80-inch minimum headroom clearance requirement.", "evidence": [{"discipline": "Architectural", "sheet": "A22.01", "source_text": "PENDANT 5'-5\" AFF", "asserted_value": "65"}], "recommended_resolution": "Verify the location of pendant light fixtures L-6 on the floor plan. Ensure they are not located in circulation paths or, if they are, raise the mounting height to provide at least 80 inches of clear headroom from the floor to the bottom of the fixture.", "code_reference": null}, {"issue_id": "VZN_CYP_005", "source_stage": "code", "category": "ada_review", "severity": "medium", "confidence": "high", "location": "Typical Restroom Details", "disciplines": ["Architectural"], "sheets": ["A51.01"], "description": "The typical rear grab bar is dimensioned as 3'-4\" (40 inches) long. A 40-inch bar may not comply with the requirement for the bar to extend at least 12 inches on one side and 24 inches on the other side of the water closet centerline.", "evidence": [{"discipline": "Architectural", "sheet": "A51.01", "source_text": "3'-4\"", "asserted_value": "40"}], "recommended_resolution": "Verify the rear grab bar dimensions and placement relative to the water closet centerline. The standard requires the bar to be a minimum of 36 inches long and extend from the centerline a minimum of 12 inches on one side and 24 inches on the other. A 36-inch or 42-inch bar is typical. The 40-inch dimension should be reviewed and corrected if it does not meet placement requirements.", "code_reference": "ADA 604.5"}, {"issue_id": "VZN_CYP_006", "source_stage": "code", "category": "building_code", "severity": "low", "confidence": "high", "location": "General Notes", "disciplines": ["Architectural"], "sheets": ["A23.01"], "description": "General note on the Finish Plan incorrectly references the 2021 IBC for interior finish compliance. The project's adopted code is the 2015 IBC.", "evidence": [{"discipline": "Architectural", "sheet": "A23.01", "source_text": "B. INTERIOR FINISHES TO COMPLY WITH IBC CLASS C OR HIGHER SECTION 803.9 AND TABLE 803.9 OF 2021 IBC.", "asserted_value": "2021 IBC"}], "recommended_resolution": "Revise the general note to reference the correct adopted code, the 2015 International Building Code (IBC).", "code_reference": null}, {"issue_id": "VZN_CYP_007", "source_stage": "code", "category": "ada_review", "severity": "low", "confidence": "high", "location": "General Notes and Finish Specifications", "disciplines": ["Architectural"], "sheets": ["A23.01"], "description": "The drawing contains conflicting requirements for floor slip resistance. General Note F requires a minimum Static Coefficient of Friction (SCOF) of 0.6, while the Polished Concrete (PC-1) specification requires a minimum SCOF of 0.50.", "evidence": [{"discipline": "Architectural", "sheet": "A23.01", "source_text": "F. ALL FLOOR FINISHES SHALL HAVE A MIN. S.C.O.F. OF .6 WET OR DRY.", "asserted_value": "0.6"}, {"discipline": "Architectural", "sheet": "A23.01", "source_text": "SLIP RESISTANCE OF FLOOR TO BE NO LESS THAN A 0.50 STATIC COEFFICIENT OF FRICTION (SCOF)", "asserted_value": "0.5"}], "recommended_resolution": "Clarify and consolidate the floor slip resistance requirement. Resolve the conflict between the 0.6 and 0.5 SCOF values. Consider specifying compliance with current industry standards, such as ANSI A326.3 for Dynamic Coefficient of Friction (DCOF), as SCOF is an outdated metric.", "code_reference": null}, {"issue_id": "VZN_CYP_008", "source_stage": "code", "category": "ada_review", "severity": "low", "confidence": "high", "location": "Areas with Carpet Tile (CPT 1)", "disciplines": ["Architectural", "Interiors"], "sheets": ["A23.01"], "description": "The specification for Carpet Tile (CPT 1) does not include the pile height. To be accessible, carpet pile height must not exceed 1/2 inch.", "evidence": [{"discipline": "Architectural", "sheet": "A23.01", "source_text": "CPT 1 CARPET TILE MANUF: SHAW PRODUCT: NEXT GEN 2.0, VERIZON STANDARD STYLE: 42JCP SIZE: 24\" X 24\" INSTALLATION: ASHLAR STACK PATTERN 50% OFFSET", "asserted_value": "Carpet tile spec missing pile height"}], "recommended_resolution": "Update the carpet tile specification to include the pile height and confirm it is 1/2 inch maximum to comply with ADA requirements.", "code_reference": "ADA 302.2"}, {"issue_id": "VZN_CYP_009", "source_stage": "code", "category": "other", "severity": "medium", "confidence": "high", "location": "Typical Restroom Details", "disciplines": ["Architectural"], "sheets": ["A51.01"], "description": "The lavatory detail shows conflicting dimensions for toe clearance, calling out both '9\" MIN. TOE CLEAR' and '6\" MAX. TOE CLEAR'. These notes are contradictory and do not clearly define the required clearances.", "evidence": [{"discipline": "Architectural", "sheet": "A51.01", "source_text": "9\" MIN. TOE CLEAR", "asserted_value": "9"}, {"discipline": "Architectural", "sheet": "A51.01", "source_text": "6\" MAX. TOE CLEAR", "asserted_value": "6"}], "recommended_resolution": "Revise the lavatory detail to remove the conflicting notes and provide clear, accurate dimensions for knee and toe clearance that comply with ADA Figure 306. For example, clarify that toe clearance must be 9 inches high minimum.", "code_reference": "ADA 606.2"}]}