Cross-discipline design-contradiction checker for construction drawing sets. Standalone tool broken out from Iron_Bid; a pipeline stage may later fold back into Iron_Bid. Pipeline: PDF->images -> per-sheet assertion extraction -> deterministic clustering by location -> per-cluster reasoning -> report. Includes CLI (cli/run_check.py) and web UI (backend/main.py). Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
1 line
4.1 KiB
JSON
1 line
4.1 KiB
JSON
{"sheet_number": "G11.01", "discipline": "General", "sheet_title": "VICINITY PLAN, ABBREVIATIONS, PROJECT GENERAL NOTES & SHEET INDEX", "level": null, "scale": null, "assertions": [{"subject": "Project", "attribute": "address", "value": "7022 ELYSON EXCHANGE WAY, CYPRESS, TX 77433", "source_text": "7022 ELYSON EXCHANGE WAY CYPRESS, TX 77433", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Project", "attribute": "building_identifier", "value": "BUILDING C", "source_text": "ELYSON TOWN CENTER - BUILDING C", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "General Requirement", "attribute": "code_reference", "value": "Through-fire-resistive walls shall conform to the authority having jurisdiction's current adopted version of the IBC and local ammendments.", "source_text": "THROUGH-FIRE-RESISTIVE WALLS SHALL CONFORM TO THE AUTHORITY HAVING JURISDICTION'S CURRENT ADOPTED VERSION OF THE IBC AND LOCAL AMMENDMENTS AS WELL AS DIRECTIVES BY THE LOCAL FIRE MARSHAL'S AUTHORITY.", "confidence": "high", "location_key": {"grid": null, "room": "PROJECT GENERAL NOTES", "level": null, "tag": "12"}}, {"subject": "Fire Extinguisher", "attribute": "max_travel_distance", "value": "75", "source_text": "PROVIDER FOR EXTINGUISHERS WITH TRAVEL DISTANCE NOT TO EXCEED 75' IN ACCORDANCE W/ NFPA STANDARD 10", "confidence": "high", "location_key": {"grid": null, "room": "PROJECT GENERAL NOTES", "level": null, "tag": "13"}}, {"subject": "Ceiling Height", "attribute": "dimension_convention", "value": "Indicated from the floor elevation to the face of the structural slab, unless otherwise noted", "source_text": "CEILING HEIGHTS SHOWN ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF THE STRUCTURAL SLAB, UNLESS SPECIFICALLY OTHERWISE NOTED.", "confidence": "high", "location_key": {"grid": null, "room": "PROJECT GENERAL NOTES", "level": null, "tag": "24"}}, {"subject": "Ceiling Height", "attribute": "dimension_convention", "value": "Indicated in RCP's are from finished floor elevation to face of suspended ceiling system or finish material", "source_text": "CEILING HEIGHTS INDICATED IN RCP'S ARE INDICATED FROM THE FINISHED FLOOR ELEVATION TO THE FACE OF SUSPENDED CEILING SYSTEM OR FACE OF FINISH MATERIAL AS SCHEDULED.", "confidence": "high", "location_key": {"grid": null, "room": "PROJECT GENERAL NOTES", "level": null, "tag": "24"}}, {"subject": "Dimensions", "attribute": "dimension_convention", "value": "Dimensions are to centerline of grid/steel unless noted otherwise.", "source_text": "DIMENSIONS ARE INDICATED TO: A. THE CENTERLINE OF THE STRUCTURAL GRID AND STRUCTURAL STEEL MEMBERS.", "confidence": "high", "location_key": {"grid": null, "room": "PROJECT GENERAL NOTES", "level": null, "tag": "25.A"}}, {"subject": "Dimensions", "attribute": "dimension_convention", "value": "Dimensions are to face of cast in place or precast concrete walls unless noted otherwise.", "source_text": "DIMENSIONS ARE INDICATED TO: B. THE FACE OF CAST IN PLACE OR PRECAST CONCRETE WALLS.", "confidence": "high", "location_key": {"grid": null, "room": "PROJECT GENERAL NOTES", "level": null, "tag": "25.B"}}, {"subject": "Dimensions", "attribute": "dimension_convention", "value": "Dimensions are to nominal face of masonry walls unless noted otherwise.", "source_text": "DIMENSIONS ARE INDICATED TO: C. THE NOMINAL FACE OF MASONRY WALLS.", "confidence": "high", "location_key": {"grid": null, "room": "PROJECT GENERAL NOTES", "level": null, "tag": "25.C"}}, {"subject": "Fire Sprinkler System", "attribute": "code_reference", "value": "NFPA STD. 13", "source_text": "THE FIRE SPRINKLER CONTRACTOR...MODIFICATIONS TO THE EXISTING AUTOMATIC FIRE SPRINKLER SYSTEM SHALL CONFORM TO NFPA STD. 13.", "confidence": "high", "location_key": {"grid": null, "room": "PROJECT GENERAL NOTES", "level": null, "tag": "34"}}, {"subject": "UL Ratings", "attribute": "wall_rating", "value": "DESIGN #U419", "source_text": "G31.06 UL RATINGS - DESIGN #U419", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}]} |