Cross-discipline design-contradiction checker for construction drawing sets. Standalone tool broken out from Iron_Bid; a pipeline stage may later fold back into Iron_Bid. Pipeline: PDF->images -> per-sheet assertion extraction -> deterministic clustering by location -> per-cluster reasoning -> report. Includes CLI (cli/run_check.py) and web UI (backend/main.py). Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
1 line
1.3 KiB
JSON
1 line
1.3 KiB
JSON
{"conflicts": [{"conflict_id": "EWH-1_drain_size_mismatch", "category": "schedule_vs_plan_mismatch", "severity": "low", "confidence": "high", "location": "Electric Water Heater EWH-1", "disciplines": ["Plumbing"], "sheets": ["P01.01", "P02.02", "P03.01"], "description": "The Plumbing Fixture Schedule on sheet P01.01 lists a 1-1/2\" waste (W) connection for the electric water heater EWH-1. This conflicts with the plan keynote on P02.02 and the installation detail on P03.01, both of which specify 3/4\" drain lines for the temperature and pressure (T&P) relief valve and the auxiliary drain pan. The remarks column of the fixture schedule itself also refers to a 3/4\" drain, creating an internal contradiction within the schedule.", "evidence": [{"discipline": "Plumbing", "sheet": "P01.01", "source_text": "W 1 - 1/2\"", "asserted_value": "1-1/2 inch Waste Connection"}, {"discipline": "Plumbing", "sheet": "P02.02", "source_text": "ROUTE 3/4\" T&P DRAIN LINE AND 3/4\" AUXILIARY DRAIN LINES TO FLOOR SINK BELOW.", "asserted_value": "3/4 inch Drain Lines"}, {"discipline": "Plumbing", "sheet": "P01.01", "source_text": "PROVIDE AUXILIARY DRAIN PAN WITH 3/4\" DRAIN TO FLOOR SINK.", "asserted_value": "3/4 inch Drain Line"}], "recommended_resolution": "coordinate drawings"}]} |