Cross-discipline design-contradiction checker for construction drawing sets. Standalone tool broken out from Iron_Bid; a pipeline stage may later fold back into Iron_Bid. Pipeline: PDF->images -> per-sheet assertion extraction -> deterministic clustering by location -> per-cluster reasoning -> report. Includes CLI (cli/run_check.py) and web UI (backend/main.py). Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
1 line
4.4 KiB
JSON
1 line
4.4 KiB
JSON
{"sheet_number": "G21.01", "discipline": "General", "sheet_title": "CODE / EXITING PLAN", "level": null, "scale": "1/4\" = 1'-0\"", "assertions": [{"subject": "Room Name", "attribute": "room_name", "value": "INVENTORY", "source_text": "INVENTORY", "confidence": "high", "location_key": {"grid": null, "room": "INVENTORY", "level": null, "tag": null}}, {"subject": "Room Name", "attribute": "room_name", "value": "LOUNGE", "source_text": "LOUNGE", "confidence": "high", "location_key": {"grid": null, "room": "LOUNGE", "level": null, "tag": null}}, {"subject": "Room Name", "attribute": "room_name", "value": "MEN'S RESTROOM", "source_text": "MEN'S RESTROOM", "confidence": "high", "location_key": {"grid": null, "room": "MEN'S RESTROOM", "level": null, "tag": null}}, {"subject": "Room Name", "attribute": "room_name", "value": "WOMEN'S RESTROOM", "source_text": "WOMEN'S RESTROOM", "confidence": "high", "location_key": {"grid": null, "room": "WOMEN'S RESTROOM", "level": null, "tag": null}}, {"subject": "Room Name", "attribute": "room_name", "value": "MANAGER'S OFFICE", "source_text": "MANAGER'S OFFICE", "confidence": "high", "location_key": {"grid": null, "room": "MANAGER'S OFFICE", "level": null, "tag": null}}, {"subject": "Room Name", "attribute": "room_name", "value": "CLEANING SUPPLIES/STORAGE", "source_text": "CLEANING SUPPLIES/STORAGE", "confidence": "high", "location_key": {"grid": null, "room": "CLEANING SUPPLIES/STORAGE", "level": null, "tag": null}}, {"subject": "Room Name", "attribute": "room_name", "value": "SALES AREA", "source_text": "SALES AREA", "confidence": "high", "location_key": {"grid": null, "room": "SALES AREA", "level": null, "tag": null}}, {"subject": "Note", "attribute": "general_note", "value": "AUTHORITY HAVING JURISDICTION: HARRIS COUNTY", "source_text": "AUTHORITY HAVING JURISDICTION: HARRIS COUNTY", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Note", "attribute": "general_note", "value": "AUTHORITY HAVING JURISDICTION (ACCESSIBILITY): STATE OF TEXAS", "source_text": "STATE OF TEXAS (ACCESSIBILITY)", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Note", "attribute": "general_note", "value": "2018 INTERNATIONAL BUILDING CODE (IBC) CH. 2-10 WITH HARRIS COUNTY AMENDMENTS", "source_text": "2018 INTERNATIONAL BUILDING CODE (IBC) CH. 2-10 WITH HARRIS COUNTY AMENDMENTS", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Note", "attribute": "general_note", "value": "2021 INTERNATIONAL FIRE CODE (IFC) WITH HARRIS COUNTY AMENDMENTS", "source_text": "2021 INTERNATIONAL FIRE CODE (IFC) WITH HARRIS COUNTY AMENDMENTS", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Note", "attribute": "general_note", "value": "2021 STATE OF TEXAS ADOPTED INTERNATIONAL MECHANICAL CODE (IMC)", "source_text": "2021 STATE OF TEXAS ADOPTED INTERNATIONAL MECHANICAL CODE (IMC)", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Note", "attribute": "general_note", "value": "2018 STATE OF TEXAS ADOPTED INTERNATIONAL PLUMBING CODE (IPC)", "source_text": "2018 STATE OF TEXAS ADOPTED INTERNATIONAL PLUMBING CODE (IPC)", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Note", "attribute": "general_note", "value": "2023 STATE OF TEXAS ADOPTED 2014 NFPA 70 NATIONAL ELECTRICAL CODE (NEC)", "source_text": "2023 STATE OF TEXAS ADOPTED 2014 NFPA 70 NATIONAL ELECTRICAL CODE (NEC)", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Note", "attribute": "general_note", "value": "2012 TEXAS ACCESSIBILITY STANDARDS", "source_text": "2012 TEXAS ACCESSIBILITY STANDARDS", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Note", "attribute": "general_note", "value": "PROJECT IS A TENANT INTERIOR REMODEL OF 3,323 SF", "source_text": "PROJECT IS A TENANT INTERIOR REMODEL OF 3,323 SF", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Note", "attribute": "general_note", "value": "THE BUILDING IS FULLY SPRINKLERED", "source_text": "THE BUILDING IS FULLY SPRINKLERED.", "confidence": "medium", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}]} |