{"conflicts": [{"conflict_id": "893d39", "category": "schedule_vs_plan_mismatch", "severity": "high", "confidence": "high", "location": "Restroom Floor", "disciplines": ["Architectural"], "sheets": ["A23.01", "A51.01"], "description": "The Finish Plan (A23.01) specifies Polished Concrete (PC-2) for the restroom floors. In contrast, the Typical Restroom Elevation detail (3/A51.01) clearly calls out 'TILE FLOOR'. These are mutually exclusive flooring materials with significant cost and constructability differences.", "evidence": [{"discipline": "Architectural", "sheet": "A23.01", "source_text": "PC-2 POLISHED CONCRETE ... GRADE: 2 (MEDIUMS EXPOSED), WITH A CLASS 1 (MATTE) FINISH ... LOCATION: CORRIDOR, RESTROOMS, LOUNGE, INVENTORY, CLEANING SUPPLIES/STORAGE", "asserted_value": "Polished Concrete"}, {"discipline": "Architectural", "sheet": "A51.01", "source_text": "TILE FLOOR (SEE A-101)", "asserted_value": "Tile Floor"}], "recommended_resolution": "coordinate drawings"}, {"conflict_id": "52f8d3", "category": "detail_vs_plan_mismatch", "severity": "medium", "confidence": "high", "location": "Restroom", "disciplines": ["Architectural"], "sheets": ["A51.01"], "description": "The Typical Restroom Elevation (2/A51.01) dimensions the side grab bar at 3'-4\" long, while the Grab Bar Blocking Detail (6/A51.01) specifies a minimum length of 3'-6\". The grab bar shown in elevation does not meet the minimum length specified in the blocking detail.", "evidence": [{"discipline": "Architectural", "sheet": "A51.01", "source_text": "3'-4\"", "asserted_value": "3'-4\""}, {"discipline": "Architectural", "sheet": "A51.01", "source_text": "3'-6\" MIN.", "asserted_value": "3'-6\" MIN."}], "recommended_resolution": "coordinate drawings"}]}