{"sheet_number": "A22.01", "discipline": "Architectural", "sheet_title": "REFLECTED CEILING PLAN", "level": null, "scale": "1/4\" = 1'-0\"", "assertions": [{"assertion_id": "A2201-GN-001", "subject": "Fire Alarm Strobe", "category": "fire_alarm", "attribute": "mounting_height_AFF", "value": "80", "unit": "in", "location_key": {"sheet_number": "A22.01", "grid": null, "room": null, "room_name": null, "level": null, "tag": null, "detail_reference": null, "plan_zone": null}, "source_text": "ALL WALL STROBES SHALL BE LOCATED @ +80\" AFF", "coordination_targets": ["electrical", "fire_alarm", "code", "ada"], "conflict_potential": "medium", "code_review_relevance": "high", "confidence": "high"}, {"assertion_id": "A2201-GN-002", "subject": "Fire Alarm Strobe", "category": "fire_alarm", "attribute": "device_location", "value": "centered in ceiling tile", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": null, "room": null, "room_name": null, "level": null, "tag": null, "detail_reference": null, "plan_zone": null}, "source_text": "ALL CEILING STROBES TO BE CENTERED IN CEILING TILE.", "coordination_targets": ["electrical", "fire_alarm", "architectural"], "conflict_potential": "low", "code_review_relevance": "low", "confidence": "high"}, {"assertion_id": "A2201-GN-003", "subject": "Fire Alarm Strobe", "category": "fire_alarm", "attribute": "device_location", "value": "align vertically with receptacle below where occurs", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": null, "room": null, "room_name": null, "level": null, "tag": null, "detail_reference": null, "plan_zone": null}, "source_text": "ALL STROBES ARE TO ALIGN VERTICALLY WITH RECEPTACLE BELOW WHERE OCCURS.", "coordination_targets": ["electrical", "fire_alarm", "architectural"], "conflict_potential": "medium", "code_review_relevance": "low", "confidence": "high"}, {"assertion_id": "A2201-GN-004", "subject": "Ceiling Device", "category": "ceiling", "attribute": "device_location", "value": "center of acoustical ceiling panel", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": null, "room": null, "room_name": null, "level": null, "tag": null, "detail_reference": null, "plan_zone": null}, "source_text": "INSTALL NEW SPRINKLER HEADS AND LIGHT FIXTURES AT THE CENTER OF THE ACOUSTICAL CEILING PANEL U.N.O.", "coordination_targets": ["electrical", "fire_protection", "architectural"], "conflict_potential": "medium", "code_review_relevance": "low", "confidence": "high"}, {"assertion_id": "A2201-GN-005", "subject": "Fire Alarm Device", "category": "fire_alarm", "attribute": "device_location", "value": "centered and aligned with light fixtures", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": null, "room": null, "room_name": null, "level": null, "tag": null, "detail_reference": null, "plan_zone": null}, "source_text": "ALL FIRE ALARM / LIFE SAFETY EQUIPMENT LOCATIONS TO BE LOCATED CENTERED AND ALIGNED WITH LIGHT FIXTURES.", "coordination_targets": ["electrical", "fire_alarm", "architectural"], "conflict_potential": "medium", "code_review_relevance": "low", "confidence": "high"}, {"assertion_id": "A2201-GN-006", "subject": "Ceiling", "category": "ceiling", "attribute": "ceiling_finish", "value": "AT-1 ACOUSTIC CEILING TILE", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": null, "room": null, "room_name": null, "level": null, "tag": null, "detail_reference": null, "plan_zone": null}, "source_text": "CEILING THROUGHOUT ENTIRE SPACE TO BE AT-1 ACOUSTIC CEILING TILE", "coordination_targets": ["architectural"], "conflict_potential": "low", "code_review_relevance": "low", "confidence": "high"}, {"assertion_id": "A2201-GN-007", "subject": "Ceiling", "category": "ceiling", "attribute": "ceiling_grid", "value": "C4-A CEILING GRID", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": null, "room": null, "room_name": null, "level": null, "tag": null, "detail_reference": null, "plan_zone": null}, "source_text": "C4-A CEILING GRID.", "coordination_targets": ["architectural"], "conflict_potential": "low", "code_review_relevance": "low", "confidence": "high"}, {"assertion_id": "A2201-SCH-001", "subject": "Light Fixture", "category": "schedule_entry", "attribute": "description", "value": "2' x 2' RECESSED INDIRECT, 4000K, 90+CRI, ACRYLIC SHEILDING, WHITE FINISH", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": null, "room": null, "room_name": null, "level": null, "tag": "L-4", "detail_reference": null, "plan_zone": null}, "source_text": "TAG: L-4, MANUF.: LITHONIA, MODEL: 2BLT2-33L-ADSM-EZ1-LP940, DESCRIPTION: 2' x 2' RECESSED INDIRECT, 4000K, 90+CRI, ACRYLIC SHEILDING, WHITE FINISH", "coordination_targets": ["electrical", "specialty"], "conflict_potential": "medium", "code_review_relevance": "none", "confidence": "high"}, {"assertion_id": "A2201-SCH-002", "subject": "Light Fixture", "category": "schedule_entry", "attribute": "description", "value": "16\" PENDANT, 2700K, DOMED LENSE, MATT BLACK", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": null, "room": null, "room_name": "Sales Area", "level": null, "tag": "L-6", "detail_reference": null, "plan_zone": "C/4.5"}, "source_text": "TAG: L-6, MANUF.: CONNEXION, MODEL: BLE-C-WHA16-106CSB20-LED16-2700K-DL, DESCRIPTION: 16\" PENDANT, 2700K, DOMED LENSE, MATT BLACK, PENDANT 5'-5\" AFF", "coordination_targets": ["electrical", "specialty"], "conflict_potential": "medium", "code_review_relevance": "none", "confidence": "high"}, {"assertion_id": "A2201-SCH-003", "subject": "Light Fixture", "category": "equipment_elev", "attribute": "mounting_height_AFF", "value": "5'-5\"", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": null, "room": null, "room_name": "Sales Area", "level": null, "tag": "L-6", "detail_reference": null, "plan_zone": "C/4.5"}, "source_text": "PENDANT 5'-5\" AFF", "coordination_targets": ["electrical", "architectural", "code", "ada"], "conflict_potential": "high", "code_review_relevance": "high", "confidence": "high"}, {"assertion_id": "A2201-RM-001", "subject": "men's restroom", "category": "room", "attribute": "room_name", "value": "MEN'S RESTROOM", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": "A/4.5", "room": null, "room_name": "MEN'S RESTROOM", "level": null, "tag": null, "detail_reference": null, "plan_zone": null}, "source_text": "MEN'S RESTROOM", "coordination_targets": ["architectural", "mechanical", "electrical", "plumbing"], "conflict_potential": "low", "code_review_relevance": "low", "confidence": "high"}, {"assertion_id": "A2201-RM-002", "subject": "women's restroom", "category": "room", "attribute": "room_name", "value": "WOMEN'S RESTROOM", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": "B/4.5", "room": null, "room_name": "WOMEN'S RESTROOM", "level": null, "tag": null, "detail_reference": null, "plan_zone": null}, "source_text": "WOMEN'S RESTROOM", "coordination_targets": ["architectural", "mechanical", "electrical", "plumbing"], "conflict_potential": "low", "code_review_relevance": "low", "confidence": "high"}, {"assertion_id": "A2201-RM-003", "subject": "room dimension", "category": "room_dimension", "attribute": "width", "value": "10'-0\"", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": "A/4.5", "room": null, "room_name": "MEN'S RESTROOM", "level": null, "tag": null, "detail_reference": null, "plan_zone": null}, "source_text": "10'-0\"", "coordination_targets": ["architectural", "structural"], "conflict_potential": "medium", "code_review_relevance": "low", "confidence": "high"}, {"assertion_id": "A2201-RM-004", "subject": "room dimension", "category": "room_dimension", "attribute": "width", "value": "10'-0\"", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": "B/4.5", "room": null, "room_name": "WOMEN'S RESTROOM", "level": null, "tag": null, "detail_reference": null, "plan_zone": null}, "source_text": "10'-0\"", "coordination_targets": ["architectural", "structural"], "conflict_potential": "medium", "code_review_relevance": "low", "confidence": "high"}, {"assertion_id": "A2201-RM-005", "subject": "Exhaust Fan", "category": "mechanical", "attribute": "fixture_location", "value": "MEN'S RESTROOM contains an exhaust fan", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": "A/4.5", "room": null, "room_name": "MEN'S RESTROOM", "level": null, "tag": null, "detail_reference": null, "plan_zone": null}, "source_text": "EXHAUST FAN", "coordination_targets": ["mechanical", "electrical", "architectural"], "conflict_potential": "high", "code_review_relevance": "medium", "confidence": "high"}, {"assertion_id": "A2201-RM-006", "subject": "Exhaust Fan", "category": "mechanical", "attribute": "fixture_location", "value": "WOMEN'S RESTROOM contains an exhaust fan", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": "B/4.5", "room": null, "room_name": "WOMEN'S RESTROOM", "level": null, "tag": null, "detail_reference": null, "plan_zone": null}, "source_text": "EXHAUST FAN", "coordination_targets": ["mechanical", "electrical", "architectural"], "conflict_potential": "high", "code_review_relevance": "medium", "confidence": "high"}, {"assertion_id": "A2201-RM-007", "subject": "Sales Area", "category": "room", "attribute": "room_name", "value": "SALES AREA", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": "C/4", "room": null, "room_name": "SALES AREA", "level": null, "tag": null, "detail_reference": null, "plan_zone": null}, "source_text": "SALES AREA", "coordination_targets": ["architectural", "mechanical", "electrical", "plumbing"], "conflict_potential": "low", "code_review_relevance": "low", "confidence": "high"}, {"assertion_id": "A2201-RM-008", "subject": "Light Fixture L-6", "category": "electrical", "attribute": "fixture_count", "value": "3", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": "C/4.5", "room": null, "room_name": "SALES AREA", "level": null, "tag": "L-6", "detail_reference": null, "plan_zone": null}, "source_text": "L-6", "coordination_targets": ["electrical", "architectural"], "conflict_potential": "low", "code_review_relevance": "none", "confidence": "high"}, {"assertion_id": "A2201-RN-001", "subject": "Building Sign", "category": "keynote_assertion", "attribute": "power_requirement", "value": "Power required for building sign", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": "D/5", "room": null, "room_name": null, "level": null, "tag": null, "detail_reference": null, "plan_zone": null}, "source_text": "PROVIDE POWER FOR BUILDING SIGN", "coordination_targets": ["electrical", "structural", "architectural", "specialty"], "conflict_potential": "high", "code_review_relevance": "low", "confidence": "high"}, {"assertion_id": "A2201-RN-002", "subject": "Building Sign", "category": "keynote_assertion", "attribute": "power_requirement", "value": "Power required for building sign", "unit": null, "location_key": {"sheet_number": "A22.01", "grid": "D/4", "room": null, "room_name": null, "level": null, "tag": null, "detail_reference": null, "plan_zone": null}, "source_text": "PROVIDE POWER FOR BUILDING SIGN", "coordination_targets": ["electrical", "structural", "architectural", "specialty"], "conflict_potential": "high", "code_review_relevance": "low", "confidence": "high"}, {"assertion_id": "A2201-EQ-001", "subject": "Ceiling Occupancy Sensor", "category": "electrical", "attribute": "fixture_count", "value": "3", "unit": null}]}