{"normalized_assertions": [{"assertion_id": "G11.04#5", "original_value": "1", "normalized_value": 1, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a numeric integer.", "source_text_preserved": true, "normalization_confidence": "high"}, {"assertion_id": "G11.04#6", "original_value": "30'-0\"", "normalized_value": 360, "normalized_unit": "in", "normalized_attribute": null, "normalization_notes": "Converted feet and inches to inches.", "source_text_preserved": true, "normalization_confidence": "high"}, {"assertion_id": "G11.04#7", "original_value": "2402160146", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is an identifier and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G11.04#8", "original_value": "2311220004", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is an identifier and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G11.04#9", "original_value": "PROJECT IS A TENANT INTERIOR LEASE SPACE BUILD OUT FOR A FIRST GENERATION RETAIL SPACE. THE SCOPE OF WORK CONSISTS OF NEW CEILINGS, FLOORING, FINISHES, NONSTRUCTURAL WALLS, ELECTRICAL, MECHANICAL AND PLUMBING", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G11.04#10", "original_value": "OCC. CLASS M, AREA SPECIFIC USE Mercantile, GROSS SF 3,323, SF PER OCC. 60, DESIGN OCC. 56", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Complex string with multiple distinct values; not suitable for scalar normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G11.04#11", "original_value": "2", "normalized_value": 2, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a numeric integer.", "source_text_preserved": true, "normalization_confidence": "high"}, {"assertion_id": "G21.01#0", "original_value": "INVENTORY", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a name and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G21.01#1", "original_value": "LOUNGE", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a name and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G21.01#2", "original_value": "MEN'S RESTROOM", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a name and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G21.01#3", "original_value": "WOMEN'S RESTROOM", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a name and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G21.01#4", "original_value": "MANAGER'S OFFICE", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a name and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G21.01#5", "original_value": "CLEANING SUPPLIES/STORAGE", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a name and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G21.01#6", "original_value": "SALES AREA", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a name and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G21.01#7", "original_value": "AUTHORITY HAVING JURISDICTION: HARRIS COUNTY", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G21.01#8", "original_value": "AUTHORITY HAVING JURISDICTION (ACCESSIBILITY): STATE OF TEXAS", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G21.01#9", "original_value": "2018 INTERNATIONAL BUILDING CODE (IBC) CH. 2-10 WITH HARRIS COUNTY AMENDMENTS", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G21.01#10", "original_value": "2021 INTERNATIONAL FIRE CODE (IFC) WITH HARRIS COUNTY AMENDMENTS", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G21.01#11", "original_value": "2021 STATE OF TEXAS ADOPTED INTERNATIONAL MECHANICAL CODE (IMC)", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G21.01#12", "original_value": "2018 STATE OF TEXAS ADOPTED INTERNATIONAL PLUMBING CODE (IPC)", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G21.01#13", "original_value": "2023 STATE OF TEXAS ADOPTED 2014 NFPA 70 NATIONAL ELECTRICAL CODE (NEC)", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G21.01#14", "original_value": "2012 TEXAS ACCESSIBILITY STANDARDS", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G21.01#15", "original_value": "PROJECT IS A TENANT INTERIOR REMODEL OF 3,323 SF", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G21.01#16", "original_value": "THE BUILDING IS FULLY SPRINKLERED", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.01#0", "original_value": "Ten (10) copies required for submittal.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.01#1", "original_value": "In case of discrepancies, the contractor shall provide the better quality or greater quantity of work at no additional cost.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.01#2", "original_value": "One electronic copy in PDF format required for submittal.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.01#3", "original_value": "Architect review time for submittals is 7 calendar days.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text; numeric value was not extracted as a specific attribute.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.01#4", "original_value": "Add an additional seven (7) calendar days for sequential review by consultants or owner.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text; numeric value was not extracted as a specific attribute.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.02#0", "original_value": "Conduct selective demolition so Owner's operations are not disrupted.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.02#1", "original_value": "A report on the presence of hazardous materials is on file for review and use.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.02#2", "original_value": "Refrigerant Recovery Technician must be certified by an EPA-approved certification program.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a requirement and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.02#3", "original_value": "Comply with ASSE A10.6 and NFPA 241.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.02#4", "original_value": "Provide extensions to existing utilities including plumbing, fire protection, electrical, and telecommunications.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a requirement and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.02#5", "original_value": "Seal voids at penetrations of fire-rated construction with fire rated material in accordance with Section 07 8400.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a requirement and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.02#6", "original_value": "01 3300", "normalized_value": "013300", "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "CSI MasterFormat number normalized to remove space.", "source_text_preserved": true, "normalization_confidence": "high"}, {"assertion_id": "G31.02#7", "original_value": "01 7000", "normalized_value": "017000", "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "CSI MasterFormat number normalized to remove space.", "source_text_preserved": true, "normalization_confidence": "high"}, {"assertion_id": "G31.02#8", "original_value": "Record measured depths of foundations in relation to finish first floor datum.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a requirement and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.02#9", "original_value": "Record measured horizontal and vertical locations of underground utilities and appurtenances.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a requirement and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.02#10", "original_value": "Record measured locations of internal utilities and appurtenances concealed in construction.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a requirement and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.02#11", "original_value": "1-1/2 inch, 2 inch maximum", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value contains multiple distinct dimension values; not suitable for scalar normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.03#0", "original_value": "Owner will occupy adjacent spaces during construction.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.03#1", "original_value": "Minimum of five years experience with related thin masonry installations.", "normalized_value": 5, "normalized_unit": "years", "normalized_attribute": "experience_duration", "normalization_notes": "Extracted minimum duration from descriptive text.", "source_text_preserved": true, "normalization_confidence": "high"}, {"assertion_id": "G31.03#2", "original_value": "Test reports shall indicate 24-hour cold water absorption, 5-hour boil absorption, saturation coefficient, initial rate of absorption, and efflorescence.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive list and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.03#3", "original_value": "48\" LONG BY 48\"", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Dimension format is ambiguous for scalar normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.03#4", "original_value": "L/360", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is in a standard format and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.03#5", "original_value": "Minimum of 3 years experience in high quality non ferrous ornamental metal work.", "normalized_value": 3, "normalized_unit": "years", "normalized_attribute": "experience_duration", "normalization_notes": "Extracted minimum duration from descriptive text.", "source_text_preserved": true, "normalization_confidence": "high"}, {"assertion_id": "G31.03#6", "original_value": "ASTM B221", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is an identifier and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.03#7", "original_value": "ASTM A1008", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is an identifier and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.03#8", "original_value": "Coordinate with foundation of wall panels, ceiling panels and trim specified in Section 064000.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a requirement and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.03#9", "original_value": "Shop applied polyester or fluoropolymer powder coat finish system with added inhibitors for exterior locations.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.04#0", "original_value": "North American Architectural Woodwork Standards (NAAWS), current edition", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is an identifier and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.04#1", "original_value": "Use fire-retardant treated MDF core for panel fabrication unless indicated otherwise.", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is a descriptive text and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.04#2", "original_value": "1/16", "normalized_value": 0.0625, "normalized_unit": "in", "normalized_attribute": null, "normalization_notes": "Converted fractional value to decimal. Unit 'inch' inferred from source text.", "source_text_preserved": true, "normalization_confidence": "high"}, {"assertion_id": "G31.04#3", "original_value": "1/32", "normalized_value": 0.03125, "normalized_unit": "in", "normalized_attribute": null, "normalization_notes": "Converted fractional value to decimal. Unit 'inch' inferred from source text.", "source_text_preserved": true, "normalization_confidence": "high"}, {"assertion_id": "G31.04#4", "original_value": "10", "normalized_value": 10, "normalized_unit": "years", "normalized_attribute": null, "normalization_notes": "Unit 'years' inferred from source text '10 YEAR WARRANTY'.", "source_text_preserved": true, "normalization_confidence": "high"}, {"assertion_id": "G31.04#5", "original_value": "1/8 inch in 10 feet, noncumulative", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Complex tolerance (ratio) is not suitable for scalar normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.04#6", "original_value": "plus or minus 1/16", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value includes a range ('plus or minus') and is not suitable for scalar normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.04#7", "original_value": "ASTM E119 or UL 263", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value lists multiple alternative standards; not suitable for scalar normalization.", "source_text_preserved": true, "normalization_confidence": null}, {"assertion_id": "G31.04#8", "original_value": "UL Assemblies", "normalized_value": null, "normalized_unit": null, "normalized_attribute": null, "normalization_notes": "Value is an identifier and does not require normalization.", "source_text_preserved": true, "normalization_confidence": null}]}