{"sheet_number": "G31.02", "discipline": "General", "sheet_title": "SPECIFICATIONS", "level": null, "scale": null, "assertions": [{"subject": "General Demolition Requirements", "attribute": "owner_occupancy", "value": "Conduct selective demolition so Owner's operations are not disrupted.", "source_text": "OWNER WILL OCCUPY PORTIONS OF BUILDING IMMEDIATELY ADJACENT TO SELECTIVE DEMOLITION AREA. CONDUCT SELECTIVE DEMOLITION SO OWNER'S OPERATIONS ARE NOT DISRUPTED.", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Hazardous Materials", "attribute": "notification_requirement", "value": "A report on the presence of hazardous materials is on file for review and use.", "source_text": "HAZARDOUS MATERIALS PRESENT IN BUILDINGS AND STRUCTURES TO BE SELECTIVELY DEMOLISHED. A REPORT ON THE PRESENCE OF HAZARDOUS MATERIALS IS ON FILE FOR REVIEW AND USE. EXAMINE REPORT AND BECOME AWARE OF LOCATIONS WHERE HAZARDOUS MATERIALS ARE PRESENT.", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Quality Assurance", "attribute": "technician_qualification", "value": "Refrigerant Recovery Technician must be certified by an EPA-approved certification program.", "source_text": "REFRIGERANT RECOVERY TECHNICIAN QUALIFICATIONS: CERTIFIED BY AN EPA-APPROVED CERTIFICATION PROGRAM.", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Fire and Life Safety", "attribute": "code_compliance", "value": "Comply with ASSE A10.6 and NFPA 241.", "source_text": "STANDARDS: COMPLY WITH ASSE A10.6 AND NFPA 241.", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Utility Systems", "attribute": "system_extension", "value": "Provide extensions to existing utilities including plumbing, fire protection, electrical, and telecommunications.", "source_text": "PROVIDE EXTENSIONS TO EXISTING UTILITIES, AS REQUIRED BY PRODUCTS AND SYSTEMS TO BE INSTALLED, INCLUDING PLUMBING, FIRE PROTECTION, ELECTRICAL, AND TELECOMMUNICATIONS.", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Fire-Rated Assemblies", "attribute": "firestopping_requirement", "value": "Seal voids at penetrations of fire-rated construction with fire rated material in accordance with Section 07 8400.", "source_text": "AT PENETRATIONS OF FIRE-RATED WALLS, PARTITIONS, OR FLOOR CONSTRUCTION, COMPLETELY SEAL VOIDS WITH FIRE RATED MATERIAL IN ACCORDANCE WITH SECTION 07 8400, TO FULL THICKNESS OF THE PENETRATED ELEMENT.", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Project Closeout", "attribute": "related_section", "value": "01 3300", "source_text": "SECTION 01 3300 - ADMINISTRATIVE REQUIREMENTS: SUBMITTALS PROCEDURES; SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Project Closeout", "attribute": "related_section", "value": "01 7000", "source_text": "SECTION 01 7000 - EXECUTION AND CLOSEOUT REQUIREMENTS: CONTRACT CLOSEOUT PROCEDURES.", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Record Documents", "attribute": "as-built_requirement", "value": "Record measured depths of foundations in relation to finish first floor datum.", "source_text": "MEASURED DEPTHS OF FOUNDATIONS IN RELATION TO FINISH FIRST FLOOR DATUM.", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Record Documents", "attribute": "as-built_requirement", "value": "Record measured horizontal and vertical locations of underground utilities and appurtenances.", "source_text": "MEASURED HORIZONTAL AND VERTICAL LOCATIONS OF UNDERGROUND UTILITIES AND APPURTENANCES, REFERENCED TO PERMANENT SURFACE IMPROVEMENTS.", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Record Documents", "attribute": "as-built_requirement", "value": "Record measured locations of internal utilities and appurtenances concealed in construction.", "source_text": "MEASURED LOCATIONS OF INTERNAL UTILITIES AND APPURTENANCES CONCEALED IN CONSTRUCTION, REFERENCED TO VISIBLE AND ACCESSIBLE FEATURES OF THE WORK.", "confidence": "high", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}, {"subject": "Operation and Maintenance Manuals", "attribute": "binder_size", "value": "1-1/2 inch, 2 inch maximum", "source_text": "PROVIDE COMMERCIAL QUALITY 1-1/2 INCH, THREE D RING BINDERS WITH DURABLE PLASTIC COVERS; 2-INCH MAXIMUM RING SIZE. WHEN MULTIPLE BINDERS ARE USED, CORRELATE DATA INTO RELATED CONSISTENT GROUPINGS.", "confidence": "medium", "location_key": {"grid": null, "room": null, "level": null, "tag": null}}]}